High Temperature Axial Extractor Fan 150°C MMotors VOK150HT Ø120mm
High Temperature Axial Extractor Fan 150°C MMotors VOK150HT Ø120mm  High Temperature Axial Extractor Fan 150°C MMotors VOK150HT Ø120mm  High Temperature Axial Extractor Fan 150°C MMotors VOK150HT Ø120mm  High Temperature Axial Extractor Fan 150°C MMotors VOK150HT Ø120mm  High Temperature Axial Extractor Fan 150°C MMotors VOK150HT Ø120mm 

High Temperature Axial Extractor Fan 150°C MMotors VOK150HT Ø120mm

  • Brand: MMotors JSC
  • Product Code: MMotors VOK150HT [120mm] 2457
  • EAN: 3800211052457
  • Availability: In Stock
  • 99.00€


Available Options

Qty
MMotors JSC VOK150HT [Ø120mm]

Axial Duct Fan for Circular High-Temperature Ducts (150°C)

The MMotors JSC VOK150HT axial fan is designed to operate safely and efficiently in high-temperature environments, with continuous operation up to 150°C. Ideal for demanding heating and ventilation systems where reliable and durable performance is required.

Key Features:

  • Metal body, lightweight and corrosion-resistant.
  • Fiberglass-reinforced plastic blades (FRP) NB40 GR30 NL, suitable for up to 150°C.
  • High-temperature motor, designed to operate at continuous 150°C.
  • Thermally reinforced wiring, safe up to 150°C.
  • NSK ball bearings (Japan), double-sealed, 30,000 h lifespan.
NSK Japan Bearings
🔥 High-Performance Fans: Continuous Operation up to 150°C 🔥

🔧 Most Common Uses:

  • ✅ Wood and pellet stoves
  • ✅ Heat recovery units and heat exchangers
  • ✅ Insert and open fireplaces
  • ✅ Domestic and industrial heating systems
  • ✅ Professional kitchens and ovens
  • ✅ Workshops and plants with high-temperature processes
  • ✅ Chemical and metallurgical installations

✨ Advantages of Installing a Fan in Your System

Using a hot air fan allows even heat distribution, increases comfort throughout the property, and optimizes wood or pellet consumption.

Thanks to its robust axial design, this model provides a consistent airflow even at high temperatures, resulting in higher energy efficiency and lower fuel costs.

  • ✔️ Better heat utilization
  • ✔️ Real energy savings
  • ✔️ More uniform and stable heat
  • ✔️ Long equipment lifespan

⚠️ Installation Tips

For safe and long-lasting performance:

  • ❌ Never install in the combustion chamber or flue.
  • ✅ Install only in hot air ducts.
  • 🔽 Lower installation: arrows pointing inward.
  • 🔼 Upper installation: arrows pointing outward.
  • ➡️ Always follow the fan’s directional arrows.

📊 Key Data

  • 🌡️ Continuous operation up to 150°C
  • 🔥 High thermal resistance materials
  • 💨 Stable and quiet axial airflow
  • ⚠️ Always respect the indicated temperature limit

Installation must be performed by qualified technicians. Returns will not be accepted if the product has been incorrectly installed or used beyond its specifications.

Keywords: fireplace fan, 120mm hot air extractor, 150°C axial fan, pellet stove fan, heat-resistant fan.

Technical Sheet – VOK150HT (Ø120 mm)
Technical Specifications
Model VOK150HT (Ø120 mm)
Rotation speed 2,650 rpm
Power consumption 46 W
Voltage (50 Hz) 230 V
Airflow 240 m³/h
Max static pressure 110 Pa
Noise level at 1 m 51 dB(A)
Duct diameter Ø120 mm
Body material Metal structure with zinc coating
Blades / color FRP (NB40 GR30 NL) / Black
Protection rating (IP) IP 44
Max air temperature 150°C
Non-return damper √ (optional)
Thermostat √ (optional)
Thermostat temperature range 50°C / 35°C
Dimensions and Design

Dimensions

Physical Dimensions
Outer Diameter ∅D 150 mm
Duct Diameter ∅d 120 mm
Dimension a 28 mm
Total Length l 150 mm
VOK150 Fan Dimensions Ø120mm
VOK150 Fan Features

⚠️ Usage Recommendation

This extractor fan must not be used for direct smoke extraction with soot (for example, stove smoke, chimney smoke, or similar) without the installation of a suitable filter.

The fan is designed for air distribution without solid particles.

Using it without a filter may cause residue buildup in the motor and components, reducing its service life and voiding the product warranty.

To ensure safe and efficient operation, always use a filtering system compatible with the type of smoke or vapor to be extracted.

⚠️ CelsiClock® 99/177 Seal

CelsiClock® 99/177 All our products are equipped with a CelsiClock® 99/177 seal that records the maximum temperature reached during use.

This seal allows verification if the equipment has been exposed to thermal conditions beyond specifications, which automatically voids the product warranty.

If the seal records a temperature above 150°C, it indicates usage not compliant with the equipment's technical specifications.

Make sure to install and use the equipment following the conditions established by the manufacturer.

Related Products

VOK150 - Ø120 mm

VOK120 – Ø100 mm

View Product
VO150 – Axial Fan 150 mm High Temperature

VO150 – Ø150 mm

View Product
VА12/2 – □120 mm

VА12/2 – □120 mm

View Product

 

 

 

Tags: axial fan, extractor fan, MMotors VOK120HT, MMotors VOK150HT, circular duct fan, hot air extractor, high temperature fan, chimney fan, pellet stove fan

Fan Specifications
Rotation speed 2.650 rpm
Input power 46 W
Voltage (50 Hz) 230 V
Airflow 240 m³/h
Max. static pressure 110 Pa
Sound level at 1 m 51 dB(A)
Duct Dimensions Ø120 mm
Body material Metal housing with zinc coating
Protection rating (IP) IP 44
Max. air temperature 150°C
Backdraft damper optional (select the option)
Thermostat optional (select the option)

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good

Related Products

High Temperature Axial Extractor Fan 150°C MMotors VOK120HT Ø100mm

High Temperature Axial Extractor Fan 150°C MMotors VOK120HT Ø100mm

MMotors JSC VOK120HT [100mm] Axial Duct Fan for Circular High-Temperature Ducts (150°C) Th..

79.00€
High Temperature Axial Fan 150°C VO120 / 120mm

High Temperature Axial Fan 150°C VO120 / 120mm

MMotors JSC VO120HT / 120 mm Axial Duct Fan for Circular High-Temperature Ducts (150°C) Th..

68.00€